EX80 SeriesELECTROMAGNETIC FLOW SENSORINSTRUCTIONSEX80 SERIES ELECTROMAGNETIC FLOW SENSOR INSTRUCTIONSEX81EX82The Leader in Flow Meter Value.ARCHIVED(
OPERATION & MAINTENANCEWhen the EX81 or 82 is powered up and there is no flow,there should be no output pulses (or, if connected to theFT420, flow
Problem Probable Cause Try...No pulse outputOutput pulsesincorrectCheck PlumbingConnect to earth groundCheck for proper electrical wiringCheck for pow
19026 72ND AVE SOUTH, KENT, WA 98032 USA(P) 253.872.0284 (F) 253.872.0285WWW.SEAMETRICS.COM 1.800.975.8153LT-11792-C06-14-04ARCHIVED(Includes Date
TABLE OF CONTENTSGeneral InformationModularity, Output, Insertion Depth, Fittings, Parts Diagram ... Page 1Instal
GENERAL INFORMATIONThe EX80-Series are electromagnetic insertion flowsensors for use in conductive liquids in pipe sizes 1” to8” (25mm to 200 mm.) Lac
Fitting Installation. EX80 Series meters require spe-cial fittings. The meter fitting must first be installed in thepipeline. Straight pipe of at l
INSTALLATIONSTRAIGHT PIPE RECOMMENDATIONS(x = diameter)5X10X5X10X5X20X5X20X30X50XReduced PipeTwo Elbows In PlaneTwo Elbows, Out Of PlaneExpanded PipeS
INSTALLATIONCaution: These flow sensors are not recommended for installation down-stream of the boiler feedwater pump where installation fault may exp
Page 5Grounding Guidelines:• For best results, use a good quality earth ground,such as metallic water piping, or a stake driveninto the ground.• If th
CONNECTIONS DIAGRAMSPage 6+_+_00987654321009876543210098765432100987654321+_S+_+_+_++__+_++__COUNTER OR PLCA055 4-20 mA OUTPUTFT520 CONTROLLERPower In
Page 7CONNECTIONS DIAGRAMS+_S+_+_+_++__+_+_+_S+_+_++__+_+_00987654321009876543210098765432100987654321+_S+_+_++__FT420 DISPLAY AND PROPORTIONAL FEEDSe